WÖHLER DP 600 - tightness measurement of flues, furnaces and 4 Pa test
DP 600 - flue gas leak measurement The DP 600 leak tester detects leaks in all types of flues specified in EN 1443 by measuring the air flow volume required to maintain the test pressure, and can also be used to perform a 4 Pa test and measure the...
Product code: 2669 Producer: Wöhler Bohemia
- Description
- Product inquiry
DP 600 - flue gas leak measurement
The DP 600 leak tester detects leaks in all types of flues specified in EN 1443 by measuring the air flow volume required to maintain the test pressure, and can also be used to perform a 4 Pa test and measure the tightness of furnaces. The measurement results can be printed via the infrared interface to the TD 100 printer or transferred to a PC using a USB cable. The main advantages of the DP 600 include:
- for all types of flues type P1, H1, N1 and N2 – menu-based operation
- test pressure as well as leakage can be set (preset according to EN 1443 N,P and H)
- Brilliant color display with easy operation
- extended range of measured fine pressure up to ± 7,000 Pa
- integrated memory for up to 100 measurements
- high fan output from 200.00 Nm3/h, suitable for measurements performed on large-volume devices
- 4 Pa test without additional pressure gauge
Main uses of the DP 600
- negative pressure flue pipes N1, N2 - test pressure 40 Pa and 20 Pa
- overpressure flue pipes P1, P2 - test pressure 200 Pa
- high-pressure flue pipes H1, H2 - test pressure 5000 Pa
Technical data
| Pressure: | |
| Measurement range: | ± 7,000 Pa |
| Distinction: | 0.1Pa: 0.0 to 900.0Pa |
| 1 Pa: from 900 Pa | |
| Accuracy: | ± 0.5 Pa, ± 2.5% of nam. values |
| Volume flow: | without adapter |
| Measurement range: | 0.0 to 200.0 Nm3/min |
| Distinction: | 0.1 Nm3/min |
| Accuracy: | ± 2.5 Nm3/min, ± 5% of measured value |
| Volume flow: | with adapter 3.0 |
| Measurement range: | 0.00 to 10.0 Nm3/min |
| Distinction: | 0.01 Nm3/min |
| Accuracy: | ± 0.05 Nm3/min, ± 5% of measured value |
| Volume flow: | with adapter 0.3 |
| Measurement range: | 0.10 to 18 NL/min |
| Distinction: | 0.01 NL/min |
| Accuracy: | ± 0.05 NL/min, ± 5% of measured value |
| General information: | |
| Pressure measurement principle: | semiconductor membrane |
| Principle of volumetric flow measurement: | anemometer |
| Power supply: | 230V, 50Hz |
| Current consumption: | max. 9 A |
| Working temperature: | 5°C to 40°C |
| Storage temperature: | -20°C to 50°C |
| Dimensions: | 330 x 360 x 150 mm |
| Weight: | 9.2 kg |
Scope of delivery
- DP 600 device
- network cable
- adapter for all leak measurements in flues (without seals)