WÖHLER DP 600 - tightness measurement of flues, furnaces and 4 Pa test

DP 600 - flue gas leak measurement The DP 600 leak tester detects leaks in all types of flues specified in EN 1443 by measuring the air flow volume required to maintain the test pressure, and can also be used to perform a 4 Pa test and measure the...

Product code: 2669       Producer: Wöhler Bohemia


in stock
4 144,89 € 3 425,53 € without VAT
Price for registered users (2% discount): 4 061,99 €
Price for registered when purchasing over 400€ € (4% discount): 3 979,09 €
-+
  • Description
  • Product inquiry

DP 600 - flue gas leak measurement

The DP 600 leak tester detects leaks in all types of flues specified in EN 1443 by measuring the air flow volume required to maintain the test pressure, and can also be used to perform a 4 Pa test and measure the tightness of furnaces. The measurement results can be printed via the infrared interface to the TD 100 printer or transferred to a PC using a USB cable. The main advantages of the DP 600 include:

  • for all types of flues type P1, H1, N1 and N2 – menu-based operation
  • test pressure as well as leakage can be set (preset according to EN 1443 N,P and H)
  • Brilliant color display with easy operation
  • extended range of measured fine pressure up to ± 7,000 Pa
  • integrated memory for up to 100 measurements
  • high fan output from 200.00 Nm3/h, suitable for measurements performed on large-volume devices
  • 4 Pa test without additional pressure gauge
Main uses of the DP 600
  • negative pressure flue pipes N1, N2 - test pressure 40 Pa and 20 Pa
  • overpressure flue pipes P1, P2 - test pressure 200 Pa
  • high-pressure flue pipes H1, H2 - test pressure 5000 Pa
Technical data
Pressure:
Measurement range: ± 7,000 Pa
Distinction: 0.1Pa: 0.0 to 900.0Pa
1 Pa: from 900 Pa
Accuracy: ± 0.5 Pa, ± 2.5% of nam. values
Volume flow: without adapter
Measurement range: 0.0 to 200.0 Nm3/min
Distinction: 0.1 Nm3/min
Accuracy: ± 2.5 Nm3/min, ± 5% of measured value
Volume flow: with adapter 3.0
Measurement range: 0.00 to 10.0 Nm3/min
Distinction: 0.01 Nm3/min
Accuracy: ± 0.05 Nm3/min, ± 5% of measured value
Volume flow: with adapter 0.3
Measurement range: 0.10 to 18 NL/min
Distinction: 0.01 NL/min
Accuracy: ± 0.05 NL/min, ± 5% of measured value
General information:
Pressure measurement principle: semiconductor membrane
Principle of volumetric flow measurement: anemometer
Power supply: 230V, 50Hz
Current consumption: max. 9 A
Working temperature: 5°C to 40°C
Storage temperature: -20°C to 50°C
Dimensions: 330 x 360 x 150 mm
Weight: 9.2 kg
Scope of delivery
  • DP 600 device
  • network cable
  • adapter for all leak measurements in flues (without seals)

Popular products
in stock
Wöhler SM 500 - dust measuring device

Wöhler SM 500 - dust measuring device

13 596,43 €
-+
in stock
CO detector Wöhler CM 220

CO detector Wöhler CM 220

159,62 €
-+
Pre-orders
Sound level meter SP 22

Sound level meter SP 22

285,77 €
Pre-orders


HAPPY NEW YEAR 2025

Dear Customers, Business Partners, We would like to thank you for your cooperation in 2024 and wish you a successful start to the new year. We greatly appreciate mutual trust and long-term...

More info