Select your country: Slovakia

Digital pressure gauge DC 410 – basic set

Wöhler DC 410 - fine pressure measurement, performing 4 Pa test accuracy - very precise usability - simple control menu, ergonomically shaped device for one-handed operation Display - brilliant color display usability - integrated data logger,...

Product code: 4277       Producer: Wöhler Bohemia


Pre-orders
1 144,29 € 953,57 € without VAT
Price for registered users (2% discount): 1 121,40 €
Price for registered when purchasing over 400€ € (4% discount): 1 098,52 €
-+
  • Description
  • Product inquiry

Wöhler DC 410 - fine pressure measurement, performing 4 Pa test

  • accuracy - very precise
  • usability - simple control menu, ergonomically shaped device for one-handed operation
  • Display - brilliant color display
  • usability - integrated data logger, possibility of printing directly on site using a thermal printer or transferring data to a computer via USB
Main use of the device
  • 4 Pa test
  • heating system check
  • measurement of flow velocity in air ducts
  • fine pressure measurement from 0.1 Pa
Technical data
Differential pressure:
Range: ± 100 hPa
Accuracy: < 3% of measured value, in operation < ± 10 Pa less than ± 0.3 Pa
Distinction: 0.1 Pa in the range ± 1100 Pa, otherwise 1 Pa
Flow rate: from 0.1 m/s
Gentle pressure:
Range: ± 100 hPa
Accuracy: < 3% of measured value, in operation < ± 10 Pa less than ± 0.15 Pa
Distinction: 0.01 Pa in the range of ± 110 Pa; 0.1 Pa in the range of ± 1,000 Pa, otherwise 1 Pa
Internal temperature:
Range: -20°C to 60°C
Accuracy: < ± 1°C
Distinction: 0.1°C
External temperature: (optional)
Range: 2 channels, -20.0°C to + 800.0°C
Accuracy: < ± 2°C in operation 0 - 133°C, otherwise 1.5% of measured value according to EN 50379-2
Distinction: 0.1°C
Humidity measurement: (optional)
Range: 0% to 100% RH (relative humidity), non-condensing
Accuracy: < ± 2% RH, in operation 10 - 90% RH, otherwise < 3% RH
Distinction: 0.1% RH
Absolute pressure: (optional)
Range: 300 hPa to 1100 hPa
Accuracy: < ± 1.5 hPa
Distinction: 0.1 hPa
Storage temperature: -20°C to 60°C
Working temperature: +5°C to 40°C
Weight: approx. 365 g (with Akku), integrated magnet
Dimensions: 80 x 225 x 60 mm
Scope of delivery
  • Wöhler DC 410 device
  • battery
  • 2 capillary tubes
  • USB cable
  • plastic suitcase