Wöhler RL 200 - coolant leak detector
The Wöhler RL 200 refrigerant detector with a sensitivity of 3 g/a reliably detects even the smallest refrigerant leaks. The Wöhler RL 200 refrigerant detector was developed in accordance with the strict guidelines of the F-gas Regulation and the...
Product code: 11361 Producer: Wöhler Bohemia
- Description
- Product inquiry
The Wöhler RL 200 refrigerant detector with a sensitivity of 3 g/a reliably detects even the smallest refrigerant leaks. The Wöhler RL 200 refrigerant detector was developed in accordance with the strict guidelines of the F-gas Regulation and the ČSN EN 14624:2012 standard and meets the highest standards in terms of environmental protection and technical accuracy.
The Wöhler RL 200 is extremely easy to use - thanks to the digital display you always have an overview of the measured values. The automatic zero setting makes handling even easier, so you can concentrate on the real task: detecting leaks in the cooling system. Increase the efficiency of your maintenance processes and minimize the potential impact on the environment - with the Wöhler RL 200 you are well equipped.
Advantages:
- sensitivity 3g/a - detection of the smallest leaks thanks to high sensitivity,
- in accordance with standards - meets the requirements of the F-gas regulation and the ČSN EN 14624:2012 standard,
- response time < 1 s.
Use:
The Wöhler RL 200 is a fast-reacting refrigerant detector for detecting leaks in refrigeration systems and heat pumps according to EN 14624:2012. The presence of refrigerant is indicated visually and by an acoustic signal.
- Accurate and reliable detection of the smallest leaks thanks to high sensitivity (3 g/a),
- meets the requirements of the F-gas regulation and the ČSN EN 14624:2012 standard,
- Easy to use thanks to digital display and automatic zero setting.
Technical data:
| Refrigerant detector: | |
| Sensitivity: | 3 g/day |
| Response time: | < 1 sec. |
| Recovery time: | 12 seconds |
| Sensor type: | semiconductor sensor |
| Zeroing: | automatic / manual |
| Lifespan: | ≥ 1 year (reduced by continuous use with high refrigerant concentration) |
| Detected refrigerants: | CFC R11, R12, R500, R503, HFCs R22, R123, R124, R502, HFCs R134a, R404a, R410a, R407C, R32, other R290, R600a, R1234YF, forming gas (95% N2 + 5% H2) |
| Alarm: | visual and audio |
| Environmental conditions and general data: | |
| Working temperature: | 0...50°C |
| Relative humidity: | < 80% RH (non-condensing) |
| Power supply: | 3x AA batteries (alkaline) |
| Battery life: | about 7 hours |
| Automatic shutdown: | after 30 minutes |
| Package dimensions: | 430 x 245 x 70 mm |
| Flexible arm (gooseneck): | length 440 mm |
| Weight: | 340g |
Scope of delivery:
- Wöhler RL 200 coolant detector,
- gooseneck 440 mm,
- battery,
- plastic case.

Camera traps