Wöhler DC 420 - for sewer pressure testing The digital device DC 420 is characterized by easy menu navigation and a unique ergonomic design. The digital device DC 420 is intended primarily for standard air testing of waste pipes according to DIN EN...
Product code: 6741 Producer: Wöhler Bohemia
- Description
- Product inquiry
Wöhler DC 420 - for sewer pressure testing
The digital device DC 420 is characterized by easy menu navigation and a unique ergonomic design. The digital device DC 420 is intended primarily for standard air testing of waste pipes according to DIN EN 1610. In case of immediate documentation of the measurement results, the digital device DC 420 can be connected to the thermal printer TD 600 (IrDA) or to a PC (mini USB). The main advantages of the digital device DC 420 include:
- Intuitive control of the test process using a brilliant color graphic display
- compact set in a suitcase - everything at hand
- printout of the graphic report directly on site
- Reel with metric markings, flexible GRP rod for precise and smooth positioning of the sealing bellows
- "intelligent" valve block for flawless connection of all components
- brilliant color display
- large measuring range: 1 Pa to 2 bar
- data transfer to PC via USB
Main use of the device
- for standard waste pipe testing
- carrying out the main air test of the sewer according to EN 1610
- for measuring volume
Technical data
| Differential pressure: | (temperature compensated) |
| Range: | ± 2 bar |
| Accuracy: | < 3% of measured value, in operation < ± 200 Pa less than ± 6 Pa |
| Distinction: | 1 Pa in operation ± 210 hPa, otherwise 10 Pa |
| Internal temperature: | |
| Range: | -20°C to 60°C |
| Accuracy: | < ± 1°C |
| Distinction: | 0.1°C |
| External temperature: | (optional, e.g. touch sensor or temperature clamp) |
| Range: | 2 channels, -20.0°C to + 800.0°C |
| Accuracy: | < ± 2°C in operation 0 - 133°C, otherwise 1.5% of measured value according to EN 50379-2 |
| Distinction: | 0.1°C |
| Humidity: | (optional) |
| Range: | 0% to 100% RH (relative humidity), non-condensing |
| Accuracy: | < ± 2% RH, in the range 0 to 90% RH, otherwise < 3% RH |
| Distinction: | 0.1% RH |
| Absolute pressure: | (optional) |
| Range: | 300 hPa to 1100 hPa |
| Accuracy: | ± 1.5 hPa |
| Distinction: | 0.1 hPa |
| General information: | |
| Power supply: | 4x AA rechargeable batteries or dry batteries |
| Interface: | USB data transfer to PC, IrDA transfer to thermal printer |
| Storage temperature: | -20°C to +60°C |
| Operating temperature: | 5°C to + 40°C |
| Weight: | approx. 450 g, integrated magnet for mounting |
| Dimensions: | 80 x 225 x 60 mm |
| Internal memory: | 2MB |
Scope of delivery
- Wöhler DC 420 device comfort set
- sealing bellows and test bellows for Ø 65 - 100 mm
- valve block
- connecting and connecting hoses in lengths of 2.4 and 6 m
- pump
- steel cable with 2 carabiners
- double-layer suitcase